Phys. Rev. Lett. 90, 150801 (2003) [4 pages]Search for Variations of Fundamental Constants using Atomic Fountain ClocksReceived 31 December 2002; published 18 April 2003 Over five years, we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser-cooled 133Cs and 87Rb atomic fountains with an accuracy of ∼10-15. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies: d/dtln[(νRb)/(νCs)]=(0.2±7.0)×10-16 yr-1 (1σ uncertainty). The same limit applies to a possible variation of the quantity (μRb/μCs)α-0.44, which involves the ratio of nuclear magnetic moments and the fine structure constant. © 2003 The American Physical Society URL:
http://link.aps.org/doi/10.1103/PhysRevLett.90.150801
DOI:
10.1103/PhysRevLett.90.150801
PACS:
06.30.Ft, 06.20.–f, 06.20.Jr, 32.80.Pj
|