corner
corner

Phys. Rev. Lett. 93, 155001 (2004) [4 pages]

Spectroscopic Diagnosis of Nested-Wire-Array Dynamics and Interpenetration at 7 MA

Download: PDF (94 kB) Buy this article Export: BibTeX or EndNote (RIS)

C. Deeney1, J. P. Apruzese2, C. A. Coverdale1, K. G. Whitney3, J. W. Thornhill2, and J. Davis2
1Sandia National Laboratories, P.O. Box 5800 Albuquerque, New Mexico 87185, USA
2Plasma Physics Division, Naval Research Laboratory, 4555 Overlook Avenue, Washington, D.C. 20375, USA
3Berkeley Scholars, Inc., Springfield, Virginia 22150, USA

See Also: Publisher's Note

Received 26 January 2004; published 4 October 2004; publisher error corrected 8 October 2004

Nested-wire array experiments have been conducted at the 7 MA level with 150 ns implosion times from an outer diameter of 40 mm. Analysis of spectral data indicates that material from the outer array preferentially occupies the high temperature core of the stagnated pinch independent of the interwire gap in the range of 1.1 to 4.5 mm.

© 2004 The American Physical Society

URL:
http://link.aps.org/doi/10.1103/PhysRevLett.93.155001
DOI:
10.1103/PhysRevLett.93.155001
PACS:
52.58.Lq, 52.59.Qy

See Also

Publisher's Note: C. Deeney, J. P. Apruzese, C. A. Coverdale, K. G. Whitney, J. W. Thornhill, and J. Davis, Publisher's Note: Spectroscopic Diagnosis of Nested-Wire-Array Dynamics and Interpenetration at 7 MA [Phys. Rev. Lett. 93, 155001 (2004)], Phys. Rev. Lett. 93, 169902 (2004).